Calibration Block

Offering you a complete choice of products which include iiw v2 calibration block, astm test block, v 1 calibration block, phased array type a reference calibration blocks, iiw-v2 calibration block and test terminal block.

Iiw V2 Calibration Block

Request Callback

₹ 2000 / Piece Get Latest Price

Length50 mm
MaterialMild Steel
FeaturesCorrosion Preventive Plating Carry Case And Calibration Cert.
ColorSilver
Packaging TypeBox
ShapeRectangular
BrandOwn Make

Minimum order quantity: 01 Piece

IIW V2 Calibration Block is a precision-engineered reference tool used for calibrating and standardizing ultrasonic testing (UT) equipment. Designed according to International Institute of Welding (IIW) specifications, this calibration block is essential for ensuring accuracy and consistency in non-destructive testing (NDT) applications.
IIW V2 calibration block for UT with carrycase and calibration certificate. Both CS and SS available. CS comes with plating to prevent from corrosion.

ASTM Test Block

Request Callback

₹ 2000 / Piece Get Latest Price

TypeUltrasonic Test Blocks
Mounting OptionPanel Mount
MaterialMild Steel
ShapeRectangular
ParameterHB
ColorGrey
Accuracy99 %

Minimum order quantity: 5 Piece

Use to check for magnetic particle deterioration, to compare different magnetic powders, to verify sensitivity or visibility or to assure field direction and strength. It contains coarse and fine surface and subsurface defects in both directions.

V 1 Calibration Block

Request Callback

₹ 9800 / Piece Get Latest Price

Length25 mm
MaterialMild Steel
FeaturesCorrosion Preventive Plating Carry Case And Calibration Cert.
ColorBrown
Model Name/NumberV1
Packaging TypeWooden Case
ShapeRectangular
BrandOwn Make
Dimension300x100

Minimum order quantity: 1 Piece

V1 Calibration Block is a precision reference tool used in ultrasonic testing (UT) to calibrate and validate the performance of ultrasonic equipment. It is essential for ensuring accuracy in thickness measurements, flaw detection, and equipment functionality checks. The V1 block adheres to international testing standards, making it a trusted choice for professionals in industries like aerospace, automotive, and manufacturing.

Phased Array Type A Reference Calibration Blocks

Request Callback

₹ 35000 / Piece Get Latest Price

Product Brochure
MaterialMild Steel
Size/Dimension440x225x140 Mm
Surface FinishingNickel Plated
Thickness25 Mm
Weight7 Kg
AdvantageHigh Quality And Competitive Price
Frequency5.0 MHz
Temperature20 Deg C
Other Deatils:

V1 and V2  are common used reference (calibration) blocks for UT testing.

Reference Block V1 allows to:

  • determine the insertion point of ultrasonic oscillations and distance from the piezoceramic plate to the probe housing with accuracy 0,5mm;
  • define the angle of input of the ultrasonic oscillations with accuracy 1 angle degree;
  • define the uncontrollable (dead) zone (for steel) straight beam ultrasonic piezoelectric transducers;
  • determine the linearity of ultrasonic scanning horizontally;
  • configure the speed and sensitivity of the scan of straight beam, angle beam and dual element piezoelectric transducers.

 

Reference Block V2 allows to:

  • calibrate the scanning of flaw detectors through the expansion velocity of ultrasonic waves, working with straight beam piezoelectric transducers;
  • calibrate the scanning of flaw detectors through the expansion velocity of ultrasonic waves, working with angle beam piezoelectric transducers;
  • set conditional sensitivity of ultrasonic flaw detectors with straight beam and angle beam piezoelectric transducers;
  • determine the output point of ultrasonic oscillations and distance from the piezoceramic plate to the probe housing;
  • define the angle of input of the ultrasonic oscillations into steel.

 

But there are available other types of blocks in accordance to different standards (ISO, DIN, etc.). If need UT or PAUT blocks of other standards, please send enquiry.

IIW-V2 Calibration Block

Request Callback

₹ 2200 / Piece Get Latest Price

MaterialAluminium
BrandCS/SS
Thickness30 mm
Country of OriginMade in India
Weight0.75 kg
Frequency50 Hz
Calibration blocks are used for calibrating machines in order to avoid mistakes. This saves time and money and also increases the integrity of industrial processes. In this write-up, we will define what calibration blocks are, their applications, and the advantages of using them for equipment standardization.

Test Terminal Block

Request Callback

₹ 2500 / Piece Get Latest Price

MaterialStainless Steel
ColorSilver
BrandMagnafield
ShapeRectangle
I Deal InNew Only
Country of OriginMade in India
Test Terminal Block is a specialized electrical component used for secure and efficient testing, monitoring, and maintenance of circuits in various applications such as control panels, switchboards, and industrial automation systems.BHEL test block is used for calibration of Magnetic particle inspection machines.     